Files
mtusi2026lab3/app/server.py
T
2026-10-13 19:11:11 +03:00

71 lines
2.2 KiB
Python

"""Entry point: uvicorn with a drain phase before the graceful shutdown.
Plain uvicorn stops accepting connections immediately on SIGTERM. Behind
HAProxy that turns every stop into a burst of refused connections until the
active health check notices. Instead, on the first signal:
t = 0 readiness -> 503, keep serving (Connection: close);
t = drain (3 s) HAProxy has marked the server DOWN (inter 1 s x fall 2),
uvicorn closes the listener and waits for in-flight
requests up to SHUTDOWN_TIMEOUT_SECONDS (8 s).
stop_grace_period in compose.yaml (15 s) is larger than 3 + 8 s.
A second signal skips the drain phase.
"""
import logging
import threading
import uvicorn
from app.config import settings
from app.lifecycle import draining
logger = logging.getLogger("messenger.server")
class DrainingServer(uvicorn.Server):
def handle_exit(self, sig, frame) -> None:
if draining.is_set():
super().handle_exit(sig, frame)
return
draining.set()
logger.warning(
"signal %s: draining for %.1f s before shutdown",
sig,
settings.shutdown_drain_seconds,
)
# Set should_exit directly instead of super().handle_exit(): uvicorn
# would re-raise the captured SIGTERM after shutdown and the process
# would exit with 143 instead of a clean 0.
timer = threading.Timer(
settings.shutdown_drain_seconds,
self._begin_shutdown,
)
timer.daemon = True
timer.start()
def _begin_shutdown(self) -> None:
logger.warning("drain finished: closing listener")
self.should_exit = True
def main() -> None:
config = uvicorn.Config(
"app.main:app",
host=settings.app_host,
port=settings.app_port,
proxy_headers=False,
# Longer than HAProxy "timeout http-keep-alive 10s": the LB closes an
# idle connection first, so it never reuses one the API just closed.
timeout_keep_alive=30,
timeout_graceful_shutdown=settings.shutdown_timeout_seconds,
log_level="info",
)
DrainingServer(config).run()
if __name__ == "__main__":