make track1-control on b1c80ee: 8x1 at 5400 rps with a pool of 4, 8 and
16 connections per worker and an LB maxconn of 16, 32 and 64 per
replica, then 4x1 against 8x0.5 on the same CPUs 7-10, three repeats
with the variants interleaved.
The first placement attempt is kept in aborted/ only as a summary: four
4x1 runs had the write command at 7-34 ms instead of 0.2-0.6 ms, waiting
on WalSync, which the CPU based rejection does not see. The rerun right
after it is the one in control-cpus. The full output of the two failed
compose up attempts names the cause of the flaky switch: all replicas
are recreated at once and lb turns unhealthy without a ready server.
Plots and capacity.md now include both control series.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01V1d3RLHNBBMA6UqBLLJv27