Record levels 3 and 4 again after the lab 2 carry over
The carry over of the lab 2 fixes changed the request pipeline, logout,
the worker shutdown budget and the stop hooks, so every level 3 and 4
record is taken again on b1c80ee: checks, own tests, smoke, stack,
storage, failover of both replicas, persistence, hooks, the lab 2 stack
tests, limits and the injected violations, lb-check, three detection
runs, failover-each and both rolling updates under k6.
All of them pass: 243 own tests, 12 stack tests, no failed request under
k6 in failover-each and in both rolling updates.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01V1d3RLHNBBMA6UqBLLJv27
This commit is contained in:
co-authored by
Claude Opus 5.5
parent
b1c80ee544
commit
f5fea5c59c
@@ -2,13 +2,13 @@
|
||||
"action": [
|
||||
"docker",
|
||||
"stop",
|
||||
"68b3f0fb15eb62d0090e56dd617344c882b8bc7e9730f1a94e69cb11deee32bd"
|
||||
"308851b9dd07c2bc70028bf7010968d5fad7cd759e7043a5eb16776c7163cc59"
|
||||
],
|
||||
"action_exit": 0,
|
||||
"action_seconds": 0.165,
|
||||
"action_seconds": 0.17,
|
||||
"lb_up_before": 2,
|
||||
"lb_up_counted_as_detected": 0,
|
||||
"detection_seconds": 1.269,
|
||||
"detection_seconds": 0.925,
|
||||
"declared_max_seconds": 1.5,
|
||||
"measurement_slack_seconds": 0.25,
|
||||
"lb_answer_after_detection": {
|
||||
@@ -17,8 +17,8 @@
|
||||
"x_instance_id_present": false,
|
||||
"error_code": "unavailable"
|
||||
},
|
||||
"restore": "docker start 68b3f0fb15eb62d0090e56dd617344c882b8bc7e9730f1a94e69cb11deee32bd && scripts/lb-wait.sh",
|
||||
"restore_seconds": 2.416,
|
||||
"restore": "docker start 308851b9dd07c2bc70028bf7010968d5fad7cd759e7043a5eb16776c7163cc59 && scripts/lb-wait.sh",
|
||||
"restore_seconds": 2.491,
|
||||
"lb_up_after_restore": 2,
|
||||
"checks": {
|
||||
"action_ok": true,
|
||||
|
||||
Reference in New Issue