Files
mtusi2026lab6/src/runtime_metrics.py
T
2026-11-25 15:56:50 +03:00

159 lines
3.4 KiB
Python

import os
import resource
import time
from threading import Lock
from opentelemetry import metrics
from opentelemetry.metrics import Observation
_lock = Lock()
_busy = 0
_backlog = 0
_oldest = 0.0
_queue_updated = 0.0
_initialized = False
_last_cpu = time.process_time()
_last_wall = time.monotonic()
def cpu_usage(options):
global _last_cpu, _last_wall
with _lock:
cpu = time.process_time()
wall = time.monotonic()
value = (cpu - _last_cpu) / max(wall - _last_wall, 0.001)
_last_cpu = cpu
_last_wall = wall
return [Observation(max(0, value) * 100)]
def memory_usage(options):
with open("/proc/self/statm", encoding="utf-8") as file:
resident = int(file.read().split()[1])
return [Observation(resident * os.sysconf("SC_PAGE_SIZE"))]
def worker_started():
global _busy
with _lock:
_busy += 1
def worker_finished():
global _busy
with _lock:
_busy -= 1
def update_queue(depth, oldest):
global _backlog, _oldest, _queue_updated
with _lock:
_backlog = int(depth)
_oldest = float(oldest)
_queue_updated = time.monotonic()
def queue_observation(field):
def callback(options):
with _lock:
if not _queue_updated:
return []
if time.monotonic() - _queue_updated > 15:
return []
value = _backlog if field == "depth" else _oldest
return [
Observation(
value,
{"queue_name": "attachment.process.v1"},
)
]
return callback
def setup_runtime_metrics(service_name):
global _initialized
if _initialized:
return
from src.database import engine, POOL_SIZE, MAX_OVERFLOW
meter = metrics.get_meter("messenger.runtime")
pool = engine.sync_engine.pool
meter.create_observable_gauge(
"messenger_process_cpu_percent",
callbacks=[cpu_usage],
)
meter.create_observable_gauge(
"messenger_process_memory_bytes",
callbacks=[memory_usage],
)
meter.create_observable_gauge(
"messenger_db_pool_used",
callbacks=[
lambda options: [Observation(pool.checkedout())]
],
)
meter.create_observable_gauge(
"messenger_db_pool_capacity",
callbacks=[
lambda options: [
Observation(POOL_SIZE + MAX_OVERFLOW)
]
],
)
meter.create_observable_gauge(
"messenger_db_pool_waiting",
callbacks=[
lambda options: [
Observation(pool.waiting_count())
]
],
)
if service_name == "messenger-worker":
meter.create_observable_gauge(
"messenger_worker_busy",
callbacks=[
lambda options: [Observation(_busy)]
],
)
meter.create_observable_gauge(
"messenger_worker_capacity",
callbacks=[
lambda options: [Observation(1)]
],
)
if service_name == "messenger-dispatcher":
meter.create_observable_gauge(
"messenger_queue_depth",
callbacks=[queue_observation("depth")],
)
meter.create_observable_gauge(
"messenger_queue_oldest_age_seconds",
callbacks=[queue_observation("oldest")],
)
_initialized = True