forked from mtusi2026/mtusi2026lab3
make track1-control on b1c80ee: 8x1 at 5400 rps with a pool of 4, 8 and
16 connections per worker and an LB maxconn of 16, 32 and 64 per
replica, then 4x1 against 8x0.5 on the same CPUs 7-10, three repeats
with the variants interleaved.
The first placement attempt is kept in aborted/ only as a summary: four
4x1 runs had the write command at 7-34 ms instead of 0.2-0.6 ms, waiting
on WalSync, which the CPU based rejection does not see. The rerun right
after it is the one in control-cpus. The full output of the two failed
compose up attempts names the cause of the flaky switch: all replicas
are recreated at once and lb turns unhealthy without a ready server.
Plots and capacity.md now include both control series.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01V1d3RLHNBBMA6UqBLLJv27
391 B
391 B
| 1 | ts | busy | total | cpus |
|---|---|---|---|---|
| 2 | 1793324136 | 5724514 | 76080079 | 16 |
| 3 | 1793324140 | 5726716 | 76085815 | 16 |
| 4 | 1793324143 | 5729527 | 76091542 | 16 |
| 5 | 1793324147 | 5732312 | 76097273 | 16 |
| 6 | 1793324151 | 5735063 | 76102977 | 16 |
| 7 | 1793324155 | 5737821 | 76108687 | 16 |
| 8 | 1793324158 | 5740609 | 76114408 | 16 |
| 9 | 1793324162 | 5743359 | 76120148 | 16 |
| 10 | 1793324166 | 5746102 | 76125864 | 16 |
| 11 | 1793324169 | 5748936 | 76131598 | 16 |
| 12 | 1793324173 | 5751668 | 76137299 | 16 |
| 13 | 1793324177 | 5754430 | 76143036 | 16 |