forked from mtusi2026/mtusi2026lab3
make track1-control on b1c80ee: 8x1 at 5400 rps with a pool of 4, 8 and
16 connections per worker and an LB maxconn of 16, 32 and 64 per
replica, then 4x1 against 8x0.5 on the same CPUs 7-10, three repeats
with the variants interleaved.
The first placement attempt is kept in aborted/ only as a summary: four
4x1 runs had the write command at 7-34 ms instead of 0.2-0.6 ms, waiting
on WalSync, which the CPU based rejection does not see. The rerun right
after it is the one in control-cpus. The full output of the two failed
compose up attempts names the cause of the flaky switch: all replicas
are recreated at once and lb turns unhealthy without a ready server.
Plots and capacity.md now include both control series.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01V1d3RLHNBBMA6UqBLLJv27
391 B
391 B
| 1 | ts | busy | total | cpus |
|---|---|---|---|---|
| 2 | 1793322970 | 5124030 | 74264217 | 16 |
| 3 | 1793322974 | 5126529 | 74269918 | 16 |
| 4 | 1793322978 | 5129699 | 74275618 | 16 |
| 5 | 1793322981 | 5132812 | 74281288 | 16 |
| 6 | 1793322985 | 5135932 | 74286958 | 16 |
| 7 | 1793322989 | 5138939 | 74292622 | 16 |
| 8 | 1793322992 | 5142063 | 74298298 | 16 |
| 9 | 1793322996 | 5145301 | 74303992 | 16 |
| 10 | 1793323000 | 5148353 | 74309686 | 16 |
| 11 | 1793323004 | 5151675 | 74315372 | 16 |
| 12 | 1793323007 | 5154902 | 74321039 | 16 |
| 13 | 1793323011 | 5157758 | 74326679 | 16 |