forked from mtusi2026/mtusi2026lab3
make track1-control on b1c80ee: 8x1 at 5400 rps with a pool of 4, 8 and
16 connections per worker and an LB maxconn of 16, 32 and 64 per
replica, then 4x1 against 8x0.5 on the same CPUs 7-10, three repeats
with the variants interleaved.
The first placement attempt is kept in aborted/ only as a summary: four
4x1 runs had the write command at 7-34 ms instead of 0.2-0.6 ms, waiting
on WalSync, which the CPU based rejection does not see. The rerun right
after it is the one in control-cpus. The full output of the two failed
compose up attempts names the cause of the flaky switch: all replicas
are recreated at once and lb turns unhealthy without a ready server.
Plots and capacity.md now include both control series.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01V1d3RLHNBBMA6UqBLLJv27
391 B
391 B
| 1 | ts | busy | total | cpus |
|---|---|---|---|---|
| 2 | 1793320185 | 4051285 | 69864148 | 16 |
| 3 | 1793320188 | 4053914 | 69869965 | 16 |
| 4 | 1793320192 | 4056798 | 69875761 | 16 |
| 5 | 1793320196 | 4059855 | 69881558 | 16 |
| 6 | 1793320199 | 4062783 | 69887353 | 16 |
| 7 | 1793320203 | 4065761 | 69893135 | 16 |
| 8 | 1793320207 | 4068776 | 69898963 | 16 |
| 9 | 1793320211 | 4071877 | 69904777 | 16 |
| 10 | 1793320214 | 4074884 | 69910562 | 16 |
| 11 | 1793320218 | 4077817 | 69916408 | 16 |
| 12 | 1793320222 | 4080876 | 69922195 | 16 |
| 13 | 1793320226 | 4083994 | 69927967 | 16 |