forked from mtusi2026/mtusi2026lab3
make track1-control on b1c80ee: 8x1 at 5400 rps with a pool of 4, 8 and
16 connections per worker and an LB maxconn of 16, 32 and 64 per
replica, then 4x1 against 8x0.5 on the same CPUs 7-10, three repeats
with the variants interleaved.
The first placement attempt is kept in aborted/ only as a summary: four
4x1 runs had the write command at 7-34 ms instead of 0.2-0.6 ms, waiting
on WalSync, which the CPU based rejection does not see. The rerun right
after it is the one in control-cpus. The full output of the two failed
compose up attempts names the cause of the flaky switch: all replicas
are recreated at once and lb turns unhealthy without a ready server.
Plots and capacity.md now include both control series.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01V1d3RLHNBBMA6UqBLLJv27
391 B
391 B
| 1 | ts | busy | total | cpus |
|---|---|---|---|---|
| 2 | 1793324479 | 5931599 | 76614022 | 16 |
| 3 | 1793324482 | 5933955 | 76619839 | 16 |
| 4 | 1793324486 | 5936668 | 76625623 | 16 |
| 5 | 1793324490 | 5939503 | 76631359 | 16 |
| 6 | 1793324494 | 5942339 | 76637132 | 16 |
| 7 | 1793324497 | 5945089 | 76642918 | 16 |
| 8 | 1793324501 | 5947851 | 76648742 | 16 |
| 9 | 1793324505 | 5950672 | 76654550 | 16 |
| 10 | 1793324508 | 5953472 | 76660324 | 16 |
| 11 | 1793324512 | 5956246 | 76666143 | 16 |
| 12 | 1793324516 | 5959048 | 76671937 | 16 |
| 13 | 1793324520 | 5961841 | 76677745 | 16 |