forked from mtusi2026/mtusi2026lab3
make track1-control on b1c80ee: 8x1 at 5400 rps with a pool of 4, 8 and
16 connections per worker and an LB maxconn of 16, 32 and 64 per
replica, then 4x1 against 8x0.5 on the same CPUs 7-10, three repeats
with the variants interleaved.
The first placement attempt is kept in aborted/ only as a summary: four
4x1 runs had the write command at 7-34 ms instead of 0.2-0.6 ms, waiting
on WalSync, which the CPU based rejection does not see. The rerun right
after it is the one in control-cpus. The full output of the two failed
compose up attempts names the cause of the flaky switch: all replicas
are recreated at once and lb turns unhealthy without a ready server.
Plots and capacity.md now include both control series.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01V1d3RLHNBBMA6UqBLLJv27
391 B
391 B
| 1 | ts | busy | total | cpus |
|---|---|---|---|---|
| 2 | 1793323948 | 5619551 | 75788013 | 16 |
| 3 | 1793323952 | 5621646 | 75793749 | 16 |
| 4 | 1793323955 | 5623897 | 75799463 | 16 |
| 5 | 1793323959 | 5626181 | 75805181 | 16 |
| 6 | 1793323963 | 5628432 | 75810914 | 16 |
| 7 | 1793323966 | 5630635 | 75816604 | 16 |
| 8 | 1793323970 | 5632857 | 75822316 | 16 |
| 9 | 1793323974 | 5635091 | 75828019 | 16 |
| 10 | 1793323978 | 5637397 | 75833706 | 16 |
| 11 | 1793323981 | 5639629 | 75839393 | 16 |
| 12 | 1793323985 | 5641805 | 75845105 | 16 |
| 13 | 1793323989 | 5644056 | 75850817 | 16 |