The LB queue does not move the peak of 8x1 (4526, 4677 and 4525 rps for
maxconn 16, 32 and 64, overlapping ranges), and the pool moves it the
other way: 4 connections per worker give 5358 rps, 16 give 3789, while
the lock waiters grow from 14.7 to 102. So the pool is not short, extra
connections only add writers to the hot chat row, which confirms the
coordination cost of the USL fit. On the same CPUs 8x0.5 peaks 7 % below
4x1 and costs 15 % more CPU per request, so the retrograde 8x1 comes from
the number of processes and connections, not from slower vCPUs.
The report also names the cause of the flaky compose up, the WalSync
stall of the dropped attempt, the disturbed control runs, and the
evidence index gets a commit column for track 1. The scenario of the
open change no longer presumes its own outcome.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01V1d3RLHNBBMA6UqBLLJv27
make faults-evidence wrote the pytest rootdir with the local home
directory, so the committed faults.txt was cleaned by hand and could not
be reproduced by the command from the report. The target now replaces
the repository path with <repo> and still fails when a stack test fails,
since the pipe through sed hides the pytest exit code.
The open review change also records that the lab 2 carry over moved the
default image tag to the compose project.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01V1d3RLHNBBMA6UqBLLJv27
An independent review of the grade 5 submission found that the level 4
measurements under load and the fault tests were taken on the code
before track 1 rewrote the message write, that the claim that the pool
and the balancer are not the bottleneck rests on reasoning alone, and
that the retrograde 8x1 result is not separated from running on other
vCPUs. Some evidence tooling also writes data of another compose
project or cannot reproduce a committed file.
The change records the order of checks on posting a message (401,
request shape 400, access 404, text 400), requires three detection runs
with the 0.25 s measurement tolerance, a docker ps of replicas after
each stop in failover-each, an upper bound of the rate grid, and control
runs that vary the pool, the balancer queue and the CPU placement one at
a time.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01V1d3RLHNBBMA6UqBLLJv27